CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM120
SP-120/240V-20A CB
COMMON TRIP, THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
168
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM230
2P-120/240V-30A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
31
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM260
2P-120/240V-60A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
20
DISCONNECT SWITCH NON-FUSED PULL-OUT
CUTLER HAMMER/EATON
DPU222R
60A 240V P-OUT
240 VAC 1 PHASE; 60 AMPERE; POWER RATING 10 HP; 2 WIRE; NON FUSIBLE FUSE; NEMA 3R; GALVANIZED STEEL ENCLOSURE; SIZE 5.4 INCH W X 3.152 INCH D X 8.7 INCH H; APPROVAL UL

Show all:  Safety Switch Accessories

 Spec Sheet   |   More Details
19
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QO120
SP-120/240V-20A CB
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 20 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; PRESSURE PLATE TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 0.75 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL, CSA; USED ON QO LOAD CENTER, NQOD PANELBOARD, OEM INTERIOR/SPEED-D[R] SWITCHBOARD DISTRIBUTION PANEL; QO[T] BRAND; QO MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
94
LOAD CENTER AND METER MAIN HUB
SQUARE D/TELEMECANIQUE
B200
2-IN BOLT-ON HUB
RAIN PROOF; 2 INCH CONDUIT; BOLT ON MOUNTING; USED ON QO[R]/HOMELINE[R] NEMA 3R LOADCENTER; APPROVAL UL

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
9
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM240
2P-120/240V-40A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
15
SQUARE D/TELEMECANIQUE
HOM816M200PFTRB
REPLACEMENT IS

Show all:  Single Phase Convertible Load Centers

 More Details
3
SQUARE D/TELEMECANIQUE
HOM3060M200PC
HOM INDR 200A MB

Show all:  Single Phase Convertible Load Centers

 More Details
5
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM250
2P-120/240V-50A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
19
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QO230
2P-120/240V-30A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 30 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; PRESSURE PLATE TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL, CSA; USED ON QO LOAD CENTER, NQOD PANELBOARD, OEM INTERIOR/SPEED-D[R] SWITCHBOARD DISTRIBUTION PANEL; QO[T] BRAND; QO MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
13
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM115
SP-120/240V-15A CB
COMMON TRIP, THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
79
SQUARE D/TELEMECANIQUE
HOM120PCAFI
MINIATURE CIRCUIT B

Show all:  Arc Fault Afci Plug-In Circuit Breakers

 More Details
30
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM220
2P-120/240V-20A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
18
LOAD CENTER AND METER MAIN HUB
SQUARE D/TELEMECANIQUE
B125
1-1/4 BOLT-ON HUB
RAIN PROOF; 1-1/4 INCH CONDUIT; BOLT ON MOUNTING; USED ON QO[R]/HOMELINE[R] NEMA 3R LOADCENTER; APPROVAL UL

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
* E=Each, C=100, M=1000