Top Sellers in Controls - Motor Control Starters, Contactors, & Renewal Pts

   
Show  items per page    First Previous  Page   of  3  Next Last
MAGNETIC STARTER
SQUARE D/TELEMECANIQUE
8536SCG3V02S
NON-REVERSING STARTER SZ1 N1 27A
FULL VOLTAGE, NON REVERSING; 7.5 HP AT 200/230 VAC 50/60 HZ, 10 HP AT 460/575 VAC 50/60 HZ 3 PHASE; 5.5 KW AT 200/230 VAC 50/60 HZ, 7.5 KW AT 460/575 VAC 50/60 HZ 3 PHASE; 27 AMPERE CURRENT RATING; 3 PHASE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; SIZE NEMA 1; NEMA 1 ENCLOSURE; OVERLOADS MELTING ALLOY THERMAL OVERLOAD RELAY; NEMA CONSTRUCTION STANDARD; 8536 MODEL; APPROVAL UL, CSA, CE; NUMBER OF POLES 3; WITH SEPARATE CONTROL CIRCUIT

Show all:  Nema Non-Combination Starters

 Spec Sheet   |   More Details
1
DEFINITE PURPOSE CONTACTOR
SQUARE D/TELEMECANIQUE
8910DPA43V02
3P 120V CONTACTOR 40 FLA
NON REVERSING; 3 POLE; 3 HP AT 115 VAC 1 PHASE, 7 1/2 HP AT 230 VAC 1 PHASE, 10 HP AT 230 VAC 3 PHASE, 20/25 HP AT 460/575 VAC 3 PHASE; 40 AMPERE CURRENT RATING; RESISTIVE CURRENT 50 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; AUXILIARY CONTACT 3NO; OPEN ENCLOSURE; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA, CE; 8910 MODEL; INCLUDES BOX LUG TERMINAL WITH QUICK CONNECT; LOCKED ROTOR RATING 240 AMPERE AT 230 VAC, 200 AMPERE AT 460 VAC, 160 AMPERE AT 575 VAC

Show all:  Definite Purpose Contactors

 Spec Sheet   |   More Details
2
CONTACTOR
SQUARE D/TELEMECANIQUE
LC1D25G7
CONTACTOR 600VAC 25AMP
NON REVERSING; 3 POLE; 2 HP AT 115 VAC, 3 HP AT 230 VAC 1 PHASE; 7.5 HP AT 200/230 VAC, 15 HP AT 460 VAC, 20 HP AT 575 VAC 3 PHASE; INDUCTIVE CURRENT 25 AMPERE (AC-3); RESISTIVE CURRENT 40 AMPERE (AC-1); COIL VOLTAGE 120 VAC AT 50/60 HZ; AUXILIARY CONTACT 1NO-1NC; OPEN; IEC CONSTRUCTION STANDARD; APPROVAL UL, CSA, ASE, BV, DEMKO, DNV, FI, NEMKO, RINA, RRS, SEMKO; LC1D MODEL

Show all:  Definite Purpose Contactors - Iec Contactors

 Spec Sheet   |   More Details
1
THERMAL UNIT
SQUARE D/TELEMECANIQUE
B45.0
THERMAL UNIT
CLASS 20, STANDARD TRIP; MOTOR FLA 51 TO 61.7 AMPERE (1 THERMAL UNIT); 1, 2, M-1, M-1P NEMA SIZE; PLUG IN MOUNTING; STANDARD PACKAGE 6; USED ON OVERLOAD RELAY

Show all:  Motor Control Starters, Etc - Thermal Overld Heater Elements

 Spec Sheet   |   More Details
6
CONTACTOR
SQUARE D/TELEMECANIQUE
LC1D32G7
CONTACTOR 600VAC 32AMP
NON REVERSING; 3 POLE; 2 HP AT 115 VAC, 5 HP AT 230 VAC 1 PHASE; 10 HP AT 200/230 VAC, 20 HP AT 460 VAC, 30 HP AT 575 VAC 3 PHASE; INDUCTIVE CURRENT 32 AMPERE (AC-3); RESISTIVE CURRENT 50 AMPERE (AC-1); COIL VOLTAGE 120 VAC AT 50/60 HZ; AUXILIARY CONTACT 1NO-1NC; OPEN; IEC CONSTRUCTION STANDARD; APPROVAL UL, CSA, ASE, BV, DEMKO, DNV, FI, NEMKO, RINA, RRS, SEMKO; LC1D MODEL

Show all:  Definite Purpose Contactors - Iec Contactors

 Spec Sheet   |   More Details
1
THERMAL UNIT
SQUARE D/TELEMECANIQUE
B28.0
THERMAL UNIT
CLASS 20, STANDARD TRIP; MOTOR FLA 30.8 TO 34.9 AMPERE (1 THERMAL UNIT); 1, M-1, M-1P NEMA SIZE; PLUG IN MOUNTING; STANDARD PACKAGE 6; USED ON OVERLOAD RELAY

Show all:  Motor Control Starters, Etc - Thermal Overld Heater Elements

 Spec Sheet   |   More Details
6
THERMAL UNIT
SQUARE D/TELEMECANIQUE
B25.0
THERMAL UNIT
CLASS 20, STANDARD TRIP; MOTOR FLA 28 TO 31.7 AMPERE (1 THERMAL UNIT); 1, M-1, M-1P NEMA SIZE; PLUG IN MOUNTING; STANDARD PACKAGE 6; USED ON OVERLOAD RELAY

Show all:  Motor Control Starters, Etc - Thermal Overld Heater Elements

 Spec Sheet   |   More Details
6
AC COIL
SQUARE D/TELEMECANIQUE
LXD1LE7
CONTACTOR COIL 208V
AC; 208 VAC AT 50/60 HZ VOLTAGE RATING; SIZE 3, 4 POLE; E7 COIL SUFFIX; USED ON TESYS[R] LC1D09 TO LC1D38/LC1DT20 TO LC1DT40 SERIES D-LINE CONTACTOR; TESYS[R] BRAND; LXD1 MODEL; POWER RATING 70 VA AT 50/60 HZ (INRUSH), 7 VA AT 50 HZ/7.5 VA AT 60 HZ (SEALED)

Show all:  Contactor Accessories

 Spec Sheet   |   More Details
1
THERMAL UNIT
SQUARE D/TELEMECANIQUE
B11.5
THERMAL UNIT
CLASS 20, STANDARD TRIP; MOTOR FLA 14.06 TO 15.85 AMPERE (1 THERMAL UNIT); 7, 8 NEMA SIZE; PLUG IN MOUNTING; STANDARD PACKAGE 6; USED ON OVERLOAD RELAY

Show all:  Motor Control Starters, Etc - Thermal Overld Heater Elements

 Spec Sheet   |   More Details
6
MAGNETIC STARTER
SQUARE D/TELEMECANIQUE
8536SDG1V02S
NON-REVERSING STARTER SZ2 N1 45A
FULL VOLTAGE, NON REVERSING; 10 HP AT 200 VAC 50/60 HZ, 15 HP AT 230 VAC 50/60 HZ, 25 HP AT 460/575 VAC 50/60 HZ 3 PHASE; 7.5 KW AT 200 VAC 50/60 HZ, 11 KW AT 230 VAC 50/60 HZ, 18.5 KW AT 460/575 VAC 50/60 HZ 3 PHASE; 45 AMPERE CURRENT RATING; 3 PHASE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; SIZE NEMA 2; NEMA 1 ENCLOSURE; OVERLOADS MELTING ALLOY THERMAL OVERLOAD RELAY; NEMA CONSTRUCTION STANDARD; 8536 MODEL; APPROVAL UL, CSA, CE; NUMBER OF POLES 3; WITH SEPARATE CONTROL CIRCUIT

Show all:  Nema Non-Combination Starters

 Spec Sheet   |   More Details
1
CONTACTOR
SQUARE D/TELEMECANIQUE
LC1D80G7
CONTACTOR 600VAC 80AMP
NON REVERSING; 3 POLE; 7.5 HP AT 115 VAC, 15 HP AT 230 VAC 1 PHASE; 25 HP AT 200 VAC, 30 HP AT 230 VAC, 60 HP AT 460/575 VAC 3 PHASE; INDUCTIVE CURRENT 80 AMPERE (AC-3); RESISTIVE CURRENT 125 AMPERE (AC-1); COIL VOLTAGE 120 VAC AT 50/60 HZ; AUXILIARY CONTACT 1NO-1NC; OPEN; IEC CONSTRUCTION STANDARD; APPROVAL UL, CSA, ASE, BV, DEMKO, DNV, FI, NEMKO, RINA, RRS, SEMKO; LC1D MODEL

Show all:  Definite Purpose Contactors - Iec Contactors

 Spec Sheet   |   More Details
1
DEFINITE PURPOSE CONTACTOR
SQUARE D/TELEMECANIQUE
8910DPA32V02
2P 120V CONTACTOR 30 FLA
NON REVERSING; 2 POLE; 2 HP AT 115 VAC 1 PHASE, 5 HP AT 230 VAC 1 PHASE, 10 HP AT 230 VAC 3 PHASE, 15/20 HP AT 460/575 VAC 3 PHASE; 30 AMPERE CURRENT RATING; RESISTIVE CURRENT 40 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; AUXILIARY CONTACT 2NO; OPEN ENCLOSURE; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA, CE; 8910 MODEL; INCLUDES BINDING HEAD SCREW TERMINAL WITH QUICK CONNECT; LOCKED ROTOR RATING 180 AMPERE AT 230 VAC, 150 AMPERE AT 460 VAC, 120 AMPERE AT 575 VAC

Show all:  Definite Purpose Contactors

 Spec Sheet   |   More Details
2
DEFINITE PURPOSE CONTACTOR
SQUARE D/TELEMECANIQUE
8910DPA33V02
3P 120V CONTACTOR 30 FLA
NON REVERSING; 3 POLE; 2 HP AT 115 VAC 1 PHASE, 5 HP AT 230 VAC 1 PHASE, 10 HP AT 230 VAC 3 PHASE, 15/20 HP AT 460/575 VAC 3 PHASE; 30 AMPERE CURRENT RATING; RESISTIVE CURRENT 40 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ, 120 VAC AT 60 HZ; AUXILIARY CONTACT 3NO; OPEN ENCLOSURE; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA, CE; 8910 MODEL; INCLUDES BINDING HEAD SCREW TERMINAL WITH QUICK CONNECT; LOCKED ROTOR RATING 180 AMPERE AT 230 VAC, 150 AMPERE AT 460 VAC, 120 AMPERE AT 575 VAC

Show all:  Definite Purpose Contactors

 Spec Sheet   |   More Details
1
CONTACTOR
SQUARE D/TELEMECANIQUE
LC1D40AG7
TESYS D 3P EVERLINK
FULL VOLTAGE, NON REVERSING; 3 POLE; 3 HP AT 115 VAC, 5 HP AT 230 VAC 1 PHASE; 10 HP AT 200/230 VAC, 30 HP AT 460/575 VAC 3 PHASE; INDUCTIVE CURRENT 40 AMPERE (AC-3); RESISTIVE CURRENT 60 AMPERE (AC-1); COIL VOLTAGE 120 VAC AT 50/60 HZ; AUXILIARY CONTACT 1NO-1NC; OPEN ENCLOSURE; IEC CONSTRUCTION STANDARD; APPROVAL UL, CSA, CE; LC1D MODEL

Show all:  Definite Purpose Contactors - Iec Contactors

 Spec Sheet   |   More Details
1
THERMAL UNIT
SQUARE D/TELEMECANIQUE
CC81.5
THERMAL UNIT
CLASS 20, STANDARD TRIP; MOTOR FLA 113 TO 122 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; STANDARD PACKAGE 6; USED ON AC MAGNETIC STARTER

Show all:  Motor Control Starters, Etc - Thermal Overld Heater Elements

 Spec Sheet   |   More Details